CDINDUSTRY ( INTERNATIONAL ) . INC marketing@cdindustry-og.com 86-23-86636683
Get Best Price quote
CDINDUSTRY ( INTERNATIONAL ) . INC Company Profile
products
Home > products > IR Flame Detector > Dual Infrared IR Flame Detector Ex ⅡC ⅢC 50m Detection Range IP67

Dual Infrared IR Flame Detector Ex ⅡC ⅢC 50m Detection Range IP67

Product Details

Place of Origin: CHINA

Brand Name: BOEN FIRE

Certification: ISO9001、CCCF、CNEX、SIL2

Model Number: JSY-F301-A1

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: Negotiable

Delivery Time: 15-20 days

Payment Terms: L/C,T/T

Get Best Price
Chat Now
Product Details
Highlight:

50m Infrared Flame Detector

,

Ex IR Flame Detector

,

Dual Infrared Flame Detector IP67

Spectrum Range:
3.8um 4.4um
Response Time:
N-heptane ≤15s
Cone Of View:
120°
Explosion Proof:
Ex Db ⅡC T6 Gb、Ex Tb IIIC T80℃ Db
IP Proof Level:
IP67
Rated Voltage:
24V DC (18V DC~36V DC)
Reset Mode:
Reset By Power-off Or Reset By Simulator
Weight:
1.35kg (2.976lbs)
Spectrum Range:
3.8um 4.4um
Response Time:
N-heptane ≤15s
Cone Of View:
120°
Explosion Proof:
Ex Db ⅡC T6 Gb、Ex Tb IIIC T80℃ Db
IP Proof Level:
IP67
Rated Voltage:
24V DC (18V DC~36V DC)
Reset Mode:
Reset By Power-off Or Reset By Simulator
Weight:
1.35kg (2.976lbs)
Product Description

Ex Dual-Infrared Flame Detector ⅡC ⅢC 50m Detection Range <15s Response

 

 

1. Product Overview

 

This flameproof dual-infrared flame detector is designed for early fire warning in scenarios with multiple fuel types. Relying on dual-infrared band detection technology, it can accurately identify the combustion characteristics of various fuels such as hydrocarbons and alcohols, achieving early warning of fire hazards.

 

The detector is equipped with 2 infrared sensors of different wavelengths, combined with a sapphire optical filter to form a dual-spectrum monitoring system. Its unique dual-band collaborative detection mechanism performs dual verification of the energy distribution and frequency characteristics of flame signals through time-domain signal waveform analysis and frequency-domain spectral feature decomposition, using Fourier fuzzy algorithms and integrating with an interference source logic database. It can effectively filter more than 95% of false alarm factors such as direct sunlight, welding sparks, and high-temperature equipment radiation, making it particularly suitable for complex environments such as oil depots, boiler rooms, and chemical storage tank areas.

 

Innovative multi-sensor data fusion algorithms and adaptive threshold adjustment technology enable the detector to maintain a fire response speed of ≤15 seconds under extreme industrial conditions such as a wide temperature range of -10°C~55°C and high humidity of 95% RH. The anti-interference design of dual-infrared bands ensures stable operation in production sites with strong electromagnetic interference, providing all-weather reliable fire protection for high-risk scenarios.

 

2. Product Features

 

(1) Integrates multi-frequency infrared technology with time-domain and frequency-domain multi-judgment mechanisms
(2) Supports flexible on-site setting of sensitivity parameters
(3) Adapts to fire monitoring scenarios for multiple fuel types
(4) Adopts patented industrial (industrial shape design)
(5) Equipped with a unique field-of-view angle adjustment marking system
(6) Features full-protection design against dust, explosion, corrosion, and rain

 

 

3. Application 

 

(1) Natural gas exploration and production enterprises
(2) Paint manufacturing, storage, and transportation links
(3) Chemical production, storage, and transportation fields
(4) Pump areas, machine rooms, and unmanned areas in power stations
(5) Petrochemical product production, storage, and transportation scenarios
(6) Flammable storage areas in large factory warehouses
(7) Solvent treatment, pressing, and drying process links in the printing industry

 

4.Main Technical Data

 

Nominal Voltage 24V DC (18V DC~36V DC)
Operating current ≤20mA
Alarm current ≤25mA / DC 24V
Ambient temperature -10~+55°C
Ambient humidity ≤95% relative humidity without condensation
Spectral response 3.8um  4.4um
Fire response time N-heptane ≤15s
Adjustable sensitivity Level I (The default level is Level I at the factory and it is locked.)
Detection angle Vertical viewing angle: 90°; Horizontal viewing angle: 120°
Protection level IP67
Output mode Standard relay output (fault, fire alarm)
Relay contact capacity 1A/AC 125V  2A/DC 30V
Material Cast aluminum (stainless steel is optional)
Implementation standard GB 15631-2008  GB 12791-2006
Dimensions φ100mm/H165mm(φ3.94in/H6.50in)
Weight (kg / lbs) 1.35kg (2.976lbs)
Color Silver, Red (Customizable)
Cable outlet thread Standard G3/4, two pieces
Explosion-proof mark Ex db C T6 Gb,Ex tb IIIC T80 Db
Detection distance Fuel Fire source size Details
N-Heptane 0.3mx0.3m(lft.x1ft.) 50m(164ft.)
Petrol 0.3mx0.3m(1ft.x 1ft.) 40m(131ft.)
Diesel fuel 0.3mx0.3m(1ft.x lft.) 35m(114ft.)
Kerosene 0.3mx0.3m(lft.x1ft.) 35m(114ft.)
Ethanol 0.3mx0.3m(lft.x lft.) 30m(98ft.)
Methane 0.5mx0.2m(1.7ft.x0.7ft.) 30m (98ft.)
Sheet of paper 0.3mx0.3m(1ft.x 1ft.) 25m(82ft.)

 

5.Indicator Lights
The JSY-F301-A flame detector is equipped with three status indicator lights, which are used to indicate its working status.

 

Status Indicator light
Operation Indicator Light (Green) Always on
Alarm Confirmation Indicator Light (Red) It blinks for early warning and is always on for an alarm.
Fault Indicator Light (Blue) When a fault occurs, the blue light is always on (and the red light goes out). When the device is powered on, it blinks to show the self-checking and self-adaptive status.

 

6.Complete Product Set

 

Name Quantities Unit of measure
JSY-F301-A1
Point-type Infrared Flame Detector
1 piece
Instruction Manual 1 copy
Explosion-proof Certificate 1 copy
Mounting Bracket 1 item
Fastenings 1 item
M8 Nut 1 piece
M8x45 Hexagon Socket Head Cap Screw 1 piece
M8x25 Hexagon Socket Head Cap Screw 1 piece
Flame Detection Remote Controller YC-F1 1 piece per batch