Product Details
Place of Origin: CHINA
Brand Name: CAILEE
Certification: ISO9001、CCCF、CNEX、SIL2
Model Number: JSY-F301-A1
Payment & Shipping Terms
Minimum Order Quantity: 1
Price: Negotiable
Delivery Time: 15-20 days
Payment Terms: L/C,T/T
Spectrum Range: |
3.8um 4.4um |
Response Time: |
N-heptane ≤15s |
Cone Of View: |
120° |
Explosion Proof: |
Ex Db ⅡC T6 Gb、Ex Tb IIIC T80℃ Db |
IP Proof Level: |
IP67 |
Alarm Current: |
≤25mA / DC 24V |
Ambient Humidity: |
≤95% Relative Humidity Without Condensation |
Spectrum Range: |
3.8um 4.4um |
Response Time: |
N-heptane ≤15s |
Cone Of View: |
120° |
Explosion Proof: |
Ex Db ⅡC T6 Gb、Ex Tb IIIC T80℃ Db |
IP Proof Level: |
IP67 |
Alarm Current: |
≤25mA / DC 24V |
Ambient Humidity: |
≤95% Relative Humidity Without Condensation |
Ex Multi-fuel Cast aluminum Scenarios Dual-Infrared Flame Detector
1. Product Overview
This flameproof dual-infrared flame detector is engineered for early fire alerts in multi-fuel environments. Leveraging dual-infrared band detection technology, it precisely identifies combustion traits of various fuels like hydrocarbons and alcohols, enabling early warning of fire risks.
Equipped with 2 infrared sensors of distinct wavelengths and paired with a sapphire optical filter, the detector forms a dual-spectrum monitoring system. Its exclusive dual-band collaborative detection mechanism verifies flame signals' energy distribution and frequency characteristics through time-domain waveform analysis and frequency-domain spectral decomposition. By utilizing Fourier fuzzy algorithms and integrating an interference source logic database, it can effectively filter over 95% of false alarm triggers such as direct sunlight, welding sparks, and high-temperature equipment radiation—making it ideal for complex settings like oil depots, boiler rooms, and chemical storage tank zones.
Innovative multi-sensor data fusion algorithms and adaptive threshold adjustment technology allow the detector to maintain a fire response time of ≤15 seconds under extreme industrial conditions, including a wide temperature range (-10°C~55°C) and high humidity (95% RH). The dual-infrared band anti-interference design ensures stable operation in production sites with strong electromagnetic interference, offering round-the-clock reliable fire protection for high-risk scenarios.
2.Product Features
(1) Combines multi-frequency infrared technology with time-domain and frequency-domain multi-judgment mechanisms
(2) Allows flexible on-site adjustment of sensitivity parameters
(3) Adapts to fire monitoring in multi-fuel scenarios
(4) Features a patented industrial design
(5) Equipped with a unique field-of-view angle adjustment marking system
(6) Boasts full protection against dust, explosion, corrosion, and rain
3. Application
(1) Natural gas exploration and production enterprises
(2) Paint manufacturing, storage, and transportation links
(3) Chemical production, storage, and transportation fields
(4) Pump areas, machine rooms, and unmanned areas in power stations
(5) Petrochemical product production, storage, and transportation scenarios
(6) Flammable storage areas in large factory warehouses
(7) Solvent treatment, pressing, and drying process links in the printing industry
4.Main Technical Data
Nominal Voltage | 24V DC (18V DC~36V DC) |
Operating current | ≤20mA |
Alarm current | ≤25mA / DC 24V |
Ambient temperature | -10~+55°C |
Ambient humidity | ≤95% relative humidity without condensation |
Spectral response | 3.8um 4.4um |
Fire response time | N-heptane ≤15s |
Adjustable sensitivity | Level I (The default level is Level I at the factory and it is locked.) |
Detection angle | Vertical viewing angle: 90°; Horizontal viewing angle: 120° |
Protection level | IP67 |
Output mode | Standard relay output (fault, fire alarm) |
Relay contact capacity | 1A/AC 125V 2A/DC 30V |
Material | Cast aluminum (stainless steel is optional) |
Implementation standard | GB 15631-2008 GB 12791-2006 |
Dimensions | φ100mm/H165mm(φ3.94in/H6.50in) |
Weight (kg / lbs) | 1.35kg (2.976lbs) |
Color | Silver, Red (Customizable) |
Cable outlet thread | Standard G3/4, two pieces |
Explosion-proof mark | Ex db ⅡC T6 Gb,Ex tb IIIC T80℃ Db |
Detection distance | Fuel | Fire source size | Details |
N-Heptane | 0.3mx0.3m(lft.x1ft.) | 50m(164ft.) | |
Petrol | 0.3mx0.3m(1ft.x 1ft.) | 40m(131ft.) | |
Diesel fuel | 0.3mx0.3m(1ft.x lft.) | 35m(114ft.) | |
Kerosene | 0.3mx0.3m(lft.x1ft.) | 35m(114ft.) | |
Ethanol | 0.3mx0.3m(lft.x lft.) | 30m(98ft.) | |
Methane | 0.5mx0.2m(1.7ft.x0.7ft.) | 30m (98ft.) | |
Sheet of paper | 0.3mx0.3m(1ft.x 1ft.) | 25m(82ft.) |
5.Indicator Lights
The JSY-F301-A flame detector is equipped with three status indicator lights, which are used to indicate its working status.
Status | Indicator light |
Operation Indicator Light (Green) | Always on |
Alarm Confirmation Indicator Light (Red) | It blinks for early warning and is always on for an alarm. |
Fault Indicator Light (Blue) | When a fault occurs, the blue light is always on (and the red light goes out). When the device is powered on, it blinks to show the self-checking and self-adaptive status. |
6.Complete Product Set
Name | Quantities | Unit of measure |
JSY-F301-A1 Point-type Infrared Flame Detector |
1 | piece |
Instruction Manual | 1 | copy |
Explosion-proof Certificate | 1 | copy |
Mounting Bracket | 1 | item |
Fastenings | 1 | item |
M8 Nut | 1 | piece |
M8x45 Hexagon Socket Head Cap Screw | 1 | piece |
M8x25 Hexagon Socket Head Cap Screw | 1 | piece |
Flame Detection Remote Controller YC-F1 | 1 | piece per batch |