Product Details
Place of Origin: CHINA
Brand Name: BOEN FIRE
Model Number: Discovery - CS1
Payment & Shipping Terms
Minimum Order Quantity: 1
Price: Negotiable
Delivery Time: 15-20 days
Payment Terms: L/C,T/T
Valve Well Type Natural Gas Leakage Detector
1.Product Overview
Discovery - CS1:
Using the technique of Time-Delayed Laser Absorption Spectroscopy (TDLAS), by measuring the intensity changes of the laser before and after passing through the detection area, the concentration of natural gas leakage can be calculated. It has the monitoring function of environmental temperature, humidity and pressure, which is used to compensate and correct the measurement results to reduce the interference of environmental factors on the detection.
2.Product Features
Discovery - CS1:
(1) High anti-interference ability, unaffected by water vapor and other gases, only responding to methane.
(2) Long sensor lifespan, high stability (lasting over 10 years).
(3) Uses wireless communication, strong communication capability, not limited by communication distance.
(4) Overall IP67 waterproof design, suitable for humid and prone-to-leakage underground environments.
(5) Overall intrinsically safe design, stable and reliable.
(6) Suitable for explosive gas mixtures of Group IIA to IIC, T1 to T4 temperature classes in Zone 1 and Zone 2 explosive hazardous areas.
(7) Can be connected to vibration signals, long-distance monitoring of leakage.
(8) Detects water level information, clarifies the working status of the equipment.
3. Application
Discovery - CS1:
It is mainly applied to the monitoring and early warning of flammable gas leakage in underground pipeline networks of urban lifelines. It can be widely used in underground valve wells and various confined spaces, such as urban gas, long-distance pipelines, comprehensive pipe galleries, petroleum, chemical, steel, fire protection, power, environmental protection, and pharmaceutical industries. It is suitable for explosive gas mixtures in Zone 1 and Zone 2 of explosion hazard areas with temperature groups IIA to IIC and T1 to T4.
4.Main Technical Data
Discovery - CS1 |
|
Item |
Description |
Measuring gases |
Methane |
Measuring principle |
Laser Absorption Spectroscopy (TDLAS) technology |
Sampling method |
Diffusive type |
Measuring range |
0~100%LEL |
Alarm error |
±3%LEL |
Response time |
T90≤10s |
Indicative value error |
±3%LEL |
Power supply duration |
≥ 3 years (under standard working mode) |
Sensor life |
≥ 10 years |
Communication |
4G/NB-loT |
Protection level |
Ip67 |
Explosion protection level |
Exib IICT4 Gb |
Operating temperature/humidity |
-40℃ ~+70℃ / ≤ 100% RH (no condensation) |
Battery voltage |
3.6V |
Power supply |
Single-use lithium battery |
Mounting method |
Wall-mounted: bracket suspension and fixation |