Product Details
Place of Origin: CHINA
Brand Name: CAILEE
Certification: ISO9001、CCCF、CNEX、SIL2
Model Number: JSY-F401-B2
Payment & Shipping Terms
Minimum Order Quantity: 1
Price: Negotiable
Delivery Time: 15-20 days
Payment Terms: L/C,T/T
Spectrum Range: |
3.8um 4.4um 5.3um 185-260nm |
Response Time: |
N-heptane ≤15s |
Ambient Temperature: |
-10~+55°C |
Alarm Current: |
≤25mA / DC 24V |
Rated Voltage: |
24V DC (18V DC~36V DC) |
Protection Level: |
IP67 |
Explosion Proof: |
Ex Db ⅡC T6 Gb、Ex Tb IIIC T80℃ Db |
Weight: |
1.35kg (2.976lbs) |
Spectrum Range: |
3.8um 4.4um 5.3um 185-260nm |
Response Time: |
N-heptane ≤15s |
Ambient Temperature: |
-10~+55°C |
Alarm Current: |
≤25mA / DC 24V |
Rated Voltage: |
24V DC (18V DC~36V DC) |
Protection Level: |
IP67 |
Explosion Proof: |
Ex Db ⅡC T6 Gb、Ex Tb IIIC T80℃ Db |
Weight: |
1.35kg (2.976lbs) |
Ex UV IR Flame Detector Four-band Broad Detection Angle Heat-resistant
1. Product Overview
This explosion-proof quad-band flame detector is engineered for early fire detection in environments with diverse fuel sources. By combining advanced infrared (three wavelengths) and ultraviolet sensing technologies, it precisely identifies combustion patterns across multiple fuel types, enabling faster alarm triggering.
The device integrates three IR sensors and one UV sensor, paired with a sapphire optical filter to create a comprehensive spectral monitoring system. It improves response times by over 30% for flames from hydrocarbons, alcohols, and other fuels. Its proprietary quad-band detection employs a multi-dimensional analysis framework, incorporating:
(1) Time-domain waveform profiling
(2) Frequency-domain spectral decomposition
(3) Fourier-based fuzzy algorithms
Coupled with an interference logic database, it eliminates >98% of false alarms caused by sunlight, welding arcs, and thermal radiation. Ideal for challenging settings like chemical plants and storage facilities.
Advanced sensor fusion algorithms and adaptive thresholding ensure consistent performance (≤15 sec response) under extreme conditions (-10°C to 55°C; 95% RH). Its enhanced sensitivity surpasses conventional detectors, delivering reliable 24/7 protection for high-risk areas.
2. Product Features
(1) Multi-band IR/UV fusion technology with dual time-frequency analysis
(2) Field-adjustable sensitivity parameters
(3) Superior EMI resistance
(4) Solar-blind false alarm suppression logic
(5) Precision FOV adjustment with visual guides
(6) Hermetic design compliant with IP66 (dust/waterproof) and explosion-proof standards
(6) Features a fully sealed structural design, meeting the four protection standards of dustproof, explosion-proof, corrosion-resistant, and rainproof
3. Application
(1) Power infrastructure: Nuclear plants, substations
(2) Oil & gas: Exploration, production sites
(3) Paint/Petrochemical: Manufacturing, storage, logistics
(4) Chemical processing and warehousing
(5) Industrial warehouses with flammable materials
(6) Printing industry: Solvent drying/pressing units
(7) Semiconductor fabrication facilities
4. Main Technical Data
Rated voltage | 24V DC (18V DC~36V DC) |
Operating current | ≤20mA |
Alarm current | ≤25mA / DC 24V |
Ambient temperature | -10~+55°C |
Ambient humidity | ≤95% relative humidity without condensation |
Spectral response | 3.8um 4.4um 5.3um 185-260nm |
Response Time | N-heptane ≤15s |
Adjustable sensitivity | Level I (The default level is Level I at the factory and it is locked.) |
Detection angle | Vertical viewing angle: 90°; Horizontal viewing angle: 120° |
Protection level | IP67 |
Output mode | Standard relay output (fault, fire alarm), 4-20mA (optional) |
Relay contact capacity | 1A/AC 125V 2A/DC 30V |
Material | Cast aluminum (stainless steel is optional) |
Implementation standard | GB15631-2008 GB12791-2006 |
Dimensions | 165mm x 136mm x 100mm(6.50in×5.35in×3.94in) |
Weight | 1.35kg(2.976lbs) |
Cable outlet thread | Standard G3/4, two pieces |
Explosion-proof mark | Ex db ⅡC T6 Gb,Ex tb IIIC T80℃ Db |
Detection distance | Fuel | Fire source size | Details |
N-Heptane | 0.3mx0.3m(lft.x1ft.) | 50m(164ft.) | |
Petrol | 0.3mx0.3m(1ft.x 1ft.) | 40m(131ft.) | |
Diesel fuel | 0.3mx0.3m(1ft.x lft.) | 35m(114ft.) | |
Kerosene | 0.3mx0.3m(lft.x1ft.) | 35m(114ft.) | |
Ethanol | 0.3mx0.3m(lft.x lft.) | 30m(98ft.) | |
Methane | 0.5mx0.2m(1.7ft.x0.7ft.) | 30m (98ft.) | |
Sheet of paper | 0.3mx0.3m(1ft.x 1ft.) | 25m(82ft.) |
5.Indicator Lights
Status | Indicator light |
Operation Indicator Light (Green) | Always on |
Alarm Confirmation Indicator Light (Red) | It flashes for early warning and stays on when in alarm. |
Fault Indicator Light (Blue) | When a fault occurs, the blue light stays on (and the red light goes out). When the device is powered on, it flashes, indicating the self-checking and self-adaptive status. |
6.Complete Product Set
Name | Quantities | Unit of measure |
JSY-F401-B2 Point-type Infrared Flame Detector Point-type Ultraviolet Flame Detector |
1 | piece |
Instruction Manual | 1 | copy |
Explosion-proof Certificate | 1 | copy |
Mounting Bracket | 1 | item |
Fastenings | 1 | item |
M8 Nut | 1 | piece |
M8x45 Hexagon Socket Head Cap Screw | 1 | piece |
M8x25 Hexagon Socket Head Cap Screw | 1 | piece |
Flame Detection Remote Controller YC-F1 | 1 | piece per batch |