CDINDUSTRY ( INTERNATIONAL ) . INC marketing@cdindustry-og.com 86-23-86636683
Get Best Price quote
CDINDUSTRY ( INTERNATIONAL ) . INC Company Profile
products
Home > products > UV IR Flame Detector > Quad Band UV IR Flame Detector 10°C~55°C Wide Temperature Range CNEX IIIC IIC

Quad Band UV IR Flame Detector 10°C~55°C Wide Temperature Range CNEX IIIC IIC

Product Details

Place of Origin: CHINA

Brand Name: BOEN FIRE

Certification: ISO9001、CCCF、CNEX、SIL2

Model Number: JSY-F401/A

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: Negotiable

Delivery Time: 15-20 days

Payment Terms: L/C,T/T

Get Best Price
Chat Now
Product Details
Highlight:

Quad Band IR Flame Detector

,

IIC UV IR Flame Detector

,

IIIC Ultraviolet Infrared Flame Detector

Spectrum Range:
3.8um 4.4um 5.3um 185-260nm
Response Time:
N-heptane ≤15s
Cone Of View:
120°
GBS:
GB12791、GB15631、GB3836
Explosion Proof:
Ex Db ⅡC T6 Gb、Ex Tb IIIC T80℃ Db
IP Proof Level:
IP67
Explosion-proof Type:
Flameproof Type
Weight:
2.976lbs
Spectrum Range:
3.8um 4.4um 5.3um 185-260nm
Response Time:
N-heptane ≤15s
Cone Of View:
120°
GBS:
GB12791、GB15631、GB3836
Explosion Proof:
Ex Db ⅡC T6 Gb、Ex Tb IIIC T80℃ Db
IP Proof Level:
IP67
Explosion-proof Type:
Flameproof Type
Weight:
2.976lbs
Product Description

CNEX IIIC IIC Quad-Band UV IR Flame Detector  -10°C~55°C Wide Temperature Range 

 

1. Product Overview

 

This explosion-proof multi-spectral flame detector integrates 3 infrared wavelength sensors and 1 ultraviolet sensor, and is equipped with a sapphire optical filter. Relying on multi-spectral detection technology, it can accurately identify the combustion flames of various fuel types. Its built-in time-domain and frequency-domain signal processing systems, combined with Fourier fuzzy algorithms and interference source logic analysis, can effectively shield interference factors such as ambient light and thermal body radiation, greatly reducing the false alarm rate. It can operate stably in both complex indoor environments and open-air sites with numerous interference sources.

 

The detector adopts special fire signal processing algorithms and coordinates the collaborative work of multiple sensors, significantly improving detection sensitivity. Even in extreme industrial environments such as high/low temperatures and high humidity, it can quickly respond and achieve early fire warning, providing a reliable guarantee for safety protection.

 

2. Product Features

 

(1) Multi-frequency infrared + ultraviolet + time domain + frequency domain multiple judgment
(2) Sensitivity:be set on-site.
(3) Self-learning function
(4) Electromagnetic interference resistance
(5) False alarm prevention, solar blind
(6) Patented, industrialized appearance design
(7) Unique field-of-view angle adjustment markings
(8) Dust-proof, explosion-proof, anti-corrosion, and rain-proof design
(9) Complies with the national standard GB 15631 - 2008 "Special Fire Detectors" and GB 12791 - 2006 "Point-type Ultraviolet Flame Detectors"

 

3. Application 

 

(1) High-risk special fire scenarios: Locations prone to deflagration risks.
(2) Key energy facilities: Nuclear power plants, converter stations, transformer zones and other core power-related areas.
(3) Industries handling flammable and explosive materials.
(4) High-hazard operation workshops.
(5) Specific industrial settings: Safety protection for pharmaceutical industry, large factory warehouses storing inflammables, and chip production workshops.

 

4.Main Technical Data

 

Rated voltage 24V DC (18V DC~36V DC)
Operating current ≤20mA
Alarm current ≤25 mA / DC 24 V
Ambient temperature -10~+55 °C
Ambient humidity ≤95% relative humidity without condensation
Spectral response 3.8µm 4.4µm 5.3µm 185-260nm
Response Time N-heptane ≤15s
Adjustable sensitivity Level I (The default level is Level I at the factory and it is locked.)
Detection angle Vertical viewing angle: 90°; Horizontal viewing angle: 120°
Protection level IP67
Output mode Standard relay output (fault, fire alarm), 4-20mA (optional)
Relay contact capacity 1A/AC 125V  2A/DC 30V
Material Cast aluminum (stainless steel is optional)
Implementation standard GB15631-2008  GB12791-2006
Dimensions 165mmx136mmx 100m(6.50in×5.35in×3.94in)
Weight 1.35kg (2.976lbs)
Cable outlet thread Standard G3/4, two pieces
Explosion-proof mark Ex db C T6 Gb,Ex tb IIIC T80 Db
Detection distance Fuel Fire source size Details
N-Heptane 0.3mx0.3m(lft.x1ft.) 50m(164ft.)
Petrol 0.3mx0.3m(1ft.x 1ft.) 40m(131ft.)
Diesel fuel 0.3mx0.3m(1ft.x lft.) 35m(114ft.)
Kerosene 0.3mx0.3m(lft.x1ft.) 35m(114ft.)
Ethanol 0.3mx0.3m(lft.x lft.) 30m(98ft.)
Methane 0.5mx0.2m(1.7ft.x0.7ft.) 30m (98ft.)
Sheet of paper 0.3mx0.3m(1ft.x 1ft.) 25m(82ft.)

 

5.Indicator Lights

 

Status Indicator light
Operation Indicator Light (Green) Always on
Alarm Confirmation Indicator Light (Red) It flashes for early warning and stays on when in alarm.
Fault Indicator Light (Blue) When a fault occurs, the blue light stays on (and the red light goes out). When the device is powered on, it flashes, indicating the self-checking and self-adaptive status.

 

6.Complete Product Set

 

Name  Quantities Unit of measure
JSY-F401/A
Point-type Infrared Flame Detector
Point-type Ultraviolet Flame Detector
1 piece
Instruction Manual 1 copy
Explosion-proof Certificate 1 copy
Mounting Bracket 1 item
Fastenings 1 item
M8 Nut 1 piece
M8x45 Hexagon Socket Head Cap Screw 1 piece
M8x25 Hexagon Socket Head Cap Screw 1 piece
Flame Detection Remote Controller YC-F1 1 piece per batch