Product Details
Place of Origin: CHINA
Brand Name: CAILEE
Certification: ISO9001、CCCF、CNEX、SIL2
Model Number: JSY-F301/A
Payment & Shipping Terms
Minimum Order Quantity: 1
Price: Negotiable
Delivery Time: 15-20 days
Payment Terms: L/C,T/T
Spectrum Range: |
3.8um 4.4um 185-260nm |
Response Time: |
N-heptane ≤15s |
Cone Of View: |
120° |
GBS: |
GB12791、GB15631、GB3836 |
Ambient Humidity: |
≤95% Relative Humidity Without Condensation |
Output Mode: |
Standard Relay Output (fault, Fire Alarm), 4-20mA |
Material: |
Cast Aluminum (stainless Steel Is Optional) |
Weight: |
1.35kg (2.976lbs) |
Spectrum Range: |
3.8um 4.4um 185-260nm |
Response Time: |
N-heptane ≤15s |
Cone Of View: |
120° |
GBS: |
GB12791、GB15631、GB3836 |
Ambient Humidity: |
≤95% Relative Humidity Without Condensation |
Output Mode: |
Standard Relay Output (fault, Fire Alarm), 4-20mA |
Material: |
Cast Aluminum (stainless Steel Is Optional) |
Weight: |
1.35kg (2.976lbs) |
Ex Point Type Triple-Band Flame Detector UV IR Multi-Criteria Judgment
1.Product Overview
This explosion-proof multi-spectral flame detector is designed for early fire warning across diverse fuel types. Equipped with dual infrared wavelength sensors, an ultraviolet sensor, and a sapphire optical filter, it delivers high responsiveness to combustion flames from various fuels.
To minimize false alarms, the detector processes multi-signal data through proprietary time-domain/frequency-domain analysis and Fourier fuzzy algorithms, combined with interference source logic judgment. This effectively eliminates interference from ambient light and thermal radiation, making it ideal for indoor/outdoor open environments with multiple potential false alarm sources.
Its advanced fire signal processing algorithms and multi-sensor technology enhance sensitivity, ensuring reliable operation in harsh industrial conditions such as extreme temperatures and high humidity.
2.Product Features
(1) Multi-dimensional detection: Combines multi-frequency infrared, ultraviolet, time-domain, and frequency-domain analysis
(2) On-site adjustable sensitivity
(3) Compatible with various fuel types
(4) Built-in self-learning function
(5) Strong electromagnetic interference resistance
(6) False alarm prevention with solar-blind technology
3. Application
(1) Large-scale industrial storage facilities housing combustible materials
(2) Spray coating workshops
(3) Pharmaceutical manufacturing sites
(4) Chemical industry: production, warehousing, and logistics operations
(5) Paint sector: manufacturing, storage, and transportation processes
(6) Petrochemical industry: production, storage, and distribution activities
4.Main Technical Data
Nominal Voltage | 24V DC (18V DC~36V DC) |
Operating current | ≤20 mA |
Alarm current | ≤25 mA / DC 24 V |
Ambient temperature | -10~+55 °C |
Ambient humidity | ≤95% relative humidity without condensation |
Spectral response | 3.8um 4.4um 185-260nm |
Fire response time | N-heptane ≤15s |
Adjustable sensitivity | Level I (The default level is Level I at the factory and it is locked.) |
Detection angle | Vertical viewing angle: 90°; Horizontal viewing angle: 120° |
Protection level | IP67 |
Output mode | Standard relay output (fault, fire alarm), 4-20mA |
Relay contact capacity | 1A/AC 125V 2A/DC 30V |
Material | Cast aluminum (stainless steel is optional) |
Implementation standard | GB 15631-2008 GB 12791-2006 |
Dimensions | φ100mm/H165mm(φ3.94in/H6.50in) |
Weight | 1.35kg (2.976lbs) |
Color | Silver, Red (Customizable) |
Cable outlet thread | Standard G3/4, two pieces |
Explosion-proof mark | Ex db ⅡC T6 Gb,Ex tb IIIC T80℃ Db |
Detection distance | Fuel | Fire source size | Details |
N-Heptane | 0.3mx0.3m(lft.x1ft.) | 50m(164ft.) | |
Petrol | 0.3mx0.3m(1ft.x 1ft.) | 40m(131ft.) | |
Diesel fuel | 0.3mx0.3m(1ft.x lft.) | 35m(114ft.) | |
Kerosene | 0.3mx0.3m(lft.x1ft.) | 35m(114ft.) | |
Ethanol | 0.3mx0.3m(lft.x lft.) | 30m(98ft.) | |
Methane | 0.5mx0.2m(1.7ft.x0.7ft.) | 30m (98ft.) | |
Sheet of paper | 0.3mx0.3m(1ft.x 1ft.) | 25m(82ft.) |
5.Indicator Lights
The JSY-F301 flame detector is equipped with three status indicator lights, which are used to indicate its working status.
Status | Indicator light |
Operation Indicator Light (Green) | Always on |
Alarm Confirmation Indicator Light (Red) | It blinks for early warning and is always on for an alarm. |
Fault Indicator Light (Blue) | When a fault occurs, the blue light is always on (and the red light goes out). When the device is powered on, it blinks to show the self-checking and self-adaptive status. |
6.Complete Product Set
Name (of a thing) | Quantities | Unit (of measure) |
JSY-F301 Point-type Infrared Flame Detector Point-type Ultraviolet Flame Detector |
1 | piece |
Instruction Manual | 1 | copy |
Explosion-proof Certificate | 1 | copy |
Mounting Bracket | 1 | item |
Connecting Piece | 1 | item |
M8 Nut | 1 | piece |
M8x45 Hexagon Socket Head Cap Screw | 1 | piece |
M8x25 Hexagon Socket Head Cap Screw | 1 | piece |
Flame Detection Remote Controller YC-F1 | 1 | 1 piece per batch |